The Everclean Unit is designed
to be on a fixed production facility where the area is classified
zone 2 gas group IIB and the temperature classification is
T3.
The Everclean Unit is designed for operation with hydraulic
oil such as Shell Tellus T15.
The Everclean Unit purifies 0.5ltrs/min of oil removing
both impurities and moisture. This particular unit is a
duel pump system which is placed at a distance from the
source of the unpurified fluid.
The system has built in logic which controls the suction
and delivery pump.
The control panel has three trip states, high high, low
low and high pressure, each sending a fault signal to the
onshore control facility.
|